服务热线
020-85250202
 
  产品时间:2025-10-09 17:56
简要描述:
Cannon粘度计/Cannon 粘度管/ Cannon手动粘度管-广州市赛拓仪器科技有限公司-Cannon粘度计/Cannon 粘度管/ Cannon手动粘度管 赛拓仪器:13602461893...
美国cannon粘度管测试方法:ASTM D445, ASTM D446, ASTM D2170方法,透明和不透明液体运动粘度测定法 (包括计算动力粘度),玻璃毛细管运动粘度计的规格及使用说明,沥青运动粘度的试验方法
CANNON Instrument Company® has been making glass capillary viscometers since 1938. We offer a variety of glass capillary viscometers because no single viscometer is ideally suited to every application. Use of high quality instruments ensures test reliability and accuracy. All CANNON glass capillary viscometers are traceable to a NIST calibration and manufactred in our ISO 9001-registered, A2LA-accredited laboratory. Our experienced staff is happy to assist you with viscometer selection. We offer the following viscometer types:
 
 1. CANNON-Fenske Routine Viscometers 
 (凯能-芬斯克普通粘度管)
 The Cannon-Fenske Routine Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 203 mm (8 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | |||
| Uncalibrated | Calibrated | Low | High | |||
| 9721-A50 | 9721-B50 | 25 | 0.002 | 0.5 | 2.0 | |
| 9721-A53 | 9721-B53 | 50 | 0.004 | 0.8 | 4.0 | |
| 9721-A56 | 9721-B56 | 75 | 0.008 | 1.6 | 8.0 | |
| 9721-A59 | 9721-B59 | 100 | 0.015 | 3.0 | 15 | |
| 9721-A62 | 9721-B62 | 150 | 0.035 | 7.0 | 35 | |
| 9721-A65 | 9721-B65 | 200 | 0.1 | 20 | 100 | |
| 9721-A68 | 9721-B68 | 300 | 0.25 | 50 | 250 | |
| 9721-A71 | 9721-B71 | 350 | 0.5 | 100 | 500 | |
| 9721-A74 | 9721-B74 | 400 | 1.2 | 240 | 1200 | |
| 9721-A77 | 9721-B77 | 450 | 2.5 | 500 | 2500 | |
| 9721-A80 | 9721-B80 | 500 | 8.0 | 1600 | 8000 | |
| 9721-A83 | 9721-B83 | 600 | 20 | 4000 | 20000 | |
| 9721-A86 | 9721-B86 | 650 | 45 | 9000 | 45000 | |
| 9721-A89 | 9721-B89 | 700 | 100 | 20000 | 100000 | |
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
 and 200 to 1000 seconds for all other sizes
  
 2. CANNON-Fenske Opaque Viscometers (Reversed Flow)
 凯能-芬斯克逆流粘度管
 The Cannon-Fenske Opaque Viscometer measures kinematic viscosity of transparent and opaque Newtonian liquids according to ASTM D445, ISO 3104 and ASTM D2170. Minimum sample volume is 12 mL. Minimum bath depth is 230 mm (9 in). Special constant viscometers are available at additional cost. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | |||
| Uncalibrated | Calibrated | Low | High | |||
| 9721-E50 | 9721-F50 | 25 | 0.002 | 0.4 | 2.0 | |
| 9721-E53 | 9721-F53 | 50 | 0.004 | 0.8 | 4.0 | |
| 9721-E56 | 9721-F56 | 75 | 0.008 | 1.6 | 8.0 | |
| 9721-E59 | 9721-F59 | 100 | 0.015 | 3.0 | 15 | |
| 9721-E62 | 9721-F62 | 150 | 0.035 | 7.0 | 35 | |
| 9721-E65 | 9721-F65 | 200 | 0.1 | 20 | 100 | |
| 9721-E68 | 9721-F68 | 300 | 0.25 | 50 | 250 | |
| 9721-E71 | 9721-F71 | 350 | 0.5 | 100 | 500 | |
| 9721-E74 | 9721-F74 | 400 | 1.2 | 240 | 1200 | |
| 9721-E77 | 9721-F77 | 450 | 2.5 | 500 | 2500 | |
| 9721-E80 | 9721-F80 | 500 | 8.0 | 1600 | 8000 | |
| 9721-E83 | 9721-F83 | 600 | 20 | 4000 | 20000 | |
| 9721-E86 | 9721-F86 | 650 | 45 | 9000 | 45000 | |
| 9721-E89 | 9721-F89 | 700 | 100 | 20000 | 100000 | |
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
 and 200 to 1000 seconds for all other sizes
  
 3. CANNON-Ubbelohde Viscometer 
 (凯能-乌氏粘度管)
 The Cannon-Ubbelohde Viscometer, with a more rugged design than standard Ubbelohde viscometers, measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 11 mL. Minimum bath depth is 254 mm (10 in) but it must be submerged to 220 mm (8.5 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | |||
| Uncalibrated | Calibrated | Low | High | |||
| 9721-J50 | 9721-K50 | 25 | 0.002 | 0.5 | 2.0 | |
| 9721-J53 | 9721-K53 | 50 | 0.004 | 0.8 | 4.0 | |
| 9721-J56 | 9721-K56 | 75 | 0.008 | 1.6 | 8.0 | |
| 9721-J59 | 9721-K59 | 100 | 0.015 | 3.0 | 15 | |
| 9721-J62 | 9721-K62 | 150 | 0.035 | 7.0 | 35 | |
| 9721-J65 | 9721-K65 | 200 | 0.1 | 20 | 100 | |
| 9721-J68 | 9721-K68 | 300 | 0.25 | 50 | 250 | |
| 9721-J71 | 9721-K71 | 350 | 0.5 | 100 | 500 | |
| 9721-J74 | 9721-K74 | 400 | 1.2 | 240 | 1200 | |
| 9721-J77 | 9721-K77 | 450 | 2.5 | 500 | 2500 | |
| 9721-J80 | 9721-K80 | 500 | 8.0 | 1600 | 8000 | |
| 9721-J83 | 9721-K83 | 600 | 20 | 4000 | 20000 | |
| 9721-J86 | 9721-K86 | 650 | 45 | 9000 | 45000 | |
| 9721-J89 | 9721-K89 | 700 | 100 | 20000 | 100000 | |
† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
  
 4. Ubbelohde Viscometers
 (乌氏粘度管)
 The Ubbelohde Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 11 mL. Minimum bath depth is 241 mm (9.5 in). Unity factor series has a constant within /- 0.2% of the values listed. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.
  
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | |||
| Uncalibrated | Calibrated | Calibrated, Unity Factor | Low | High | ||
| 9721-N50 | 9721-R50 | 9721-U50 | 0 | 0.001 | 0.3 | 1.0 | 
| 9721-N53 | 9721-R53 | 9721-U53 | 0C | 0.003 | 0.6 | 3.0 | 
| 9721-N56 | 9721-R56 | 9721-U56 | 0B | 0.005 | 1.0 | 5.0 | 
| 9721-N59 | 9721-R59 | 9721-U59 | 1 | 0.01 | 2.0 | 10 | 
| 9721-N62 | 9721-R62 | 9721-U62 | 1C | 0.03 | 6.0 | 30 | 
| 9721-N65 | 9721-R65 | 9721-U65 | 1B | 0.05 | 10 | 50 | 
| 9721-N68 | 9721-R68 | 9721-U68 | 2 | 0.1 | 20 | 100 | 
| 9721-N71 | 9721-R71 | 9721-U71 | 2C | 0.3 | 60 | 300 | 
| 9721-N74 | 9721-R74 | 9721-U74 | 2B | 0.5 | 100 | 500 | 
| 9721-N77 | 9721-R77 | 9721-U77 | 3 | 1.0 | 200 | 1000 | 
| 9721-N80 | 9721-R80 | 9721-U80 | 3C | 3.0 | 600 | 3000 | 
| 9721-N83 | 9721-R83 | 9721-U83 | 3B | 5.0 | 1000 | 5000 | 
| 9721-N86 | 9721-R86 | 9721-U86 | 4 | 10 | 2000 | 10000 | 
| 9721-N89 | 9721-R89 | 9721-U89 | 4C | 30 | 6000 | 30000 | 
| 9721-N92 | 9721-R92 | 9721-U92 | 4B | 50 | 10000 | 50000 | 
| 9721-N95 | 9721-R95 | 9721-U95 | 5 | 100 | 20000 | 100000 | 
† Viscosity ranges in mm²/s represent flow times of 300 to 1000 seconds for size 0
 and 200 to 1000 seconds for all other sizes
 The Ubbelohde Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 11 mL. Minimum bath depth is 241 mm (9.5 in). Unity factor series has a constant within /- 0.2% of the values listed. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.
  
 5. CANNON-Ubbelohde Dilution Viscometers
 凯能-乌氏粘度管 (稀释型)
 The Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 8 mL (can be diluted to 40 mL). Minimum bath depth is 305 mm (12 in). The CANNON CT-518 bath is recommended. (CT-500 and CT-600 baths are not deep enough.) Viscometer constant is the same at all temperatures. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.
|  | Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | ||
| Uncalibrated | Calibrated | Low | High | |||
| 9722-L50 | 9722-M50 | 25 | 0.002 | 0.5 | 2.0 | |
| 9722-L53 | 9722-M53 | 50 | 0.004 | 0.8 | 4.0 | |
| 9722-L56 | 9722-M56 | 75 | 0.008 | 1.6 | 8.0 | |
| 9722-L59 | 9722-M59 | 100 | 0.015 | 3.0 | 15 | |
| 9722-L62 | 9722-M62 | 150 | 0.035 | 7.0 | 35 | |
| 9722-L65 | 9722-M65 | 200 | 0.1 | 20 | 100 | |
| 9722-L68 | 9722-M68 | 300 | 0.25 | 50 | 250 | |
| 9722-L71 | 9722-M71 | 350 | 0.5 | 100 | 500 | |
| 9722-L74 | 9722-M74 | 400 | 1.2 | 240 | 1200 | |
| 9722-L77 | 9722-M77 | 450 | 2.5 | 500 | 2500 | |
| 9722-L80 | 9722-M80 | 500 | 8.0 | 1600 | 8000 | |
| 9722-L83 | 9722-M83 | 600 | 20 | 4000 | 20000 | |
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
 and 200 to 1000 seconds for all other sizes
  
 6. CANNON-Ubbelohde Semi-Micro Viscometers
 凯能-乌氏半微量粘度管
 The Cannon-Ubbelohde Semi-Micro Viscometer measures kinematic viscosity of small samples of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is ~1 mL (sizes 400 through 600 may require additional sample). Initial sample can be diluted as much as 20 mL for intrinsic viscosity determinations. Minimum bath depth is 240 mm (9.5 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | |||
| Uncalibrated | Calibrated | Low | High | |||
| 9722-G50 | 9722-H50 | 25 | 0.002 | 0.4 | 2.0 | |
| 9722-G53 | 9722-H53 | 50 | 0.004 | 0.8 | 4.0 | |
| 9722-G56 | 9722-H56 | 75 | 0.008 | 1.6 | 8.0 | |
| 9722-G59 | 9722-H59 | 100 | 0.015 | 3.0 | 15 | |
| 9722-G62 | 9722-H62 | 150 | 0.035 | 7.0 | 35 | |
| 9722-G65 | 9722-H65 | 200 | 0.1 | 20 | 100 | |
| 9722-G68 | 9722-H68 | 300 | 0.25 | 50 | 250 | |
| 9722-G71 | 9722-H71 | 350 | 0.5 | 100 | 500 | |
| 9722-G74 | 9722-H74 | 400 | 1.2 | 240 | 1200 | |
| 9722-G77 | 9722-H77 | 450 | 2.5 | 500 | 2500 | |
| 9722-G80 | 9722-H80 | 500 | 8.0 | 1600 | 8000 | |
| 9722-G83 | 9722-H83 | 600 | 20 | 4000 | 20000 | |
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
 and 200 to 1000 seconds for all other sizes
 7. 10-fold CANNON-Ubbelohde 4-Bulb Shear Viscometers
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | Shear Rate at Wall, reciprocal seconds | ||||
| Uncalibrated | Calibrated | Low | High | Low | High | |||
| 9723-L50 | 9723-M50 | 25 | 0.002 | 0.4 | 2.0 | 82 | 3300 | |
| 9723-L53 | 9723-M53 | 50 | 0.004 | 0.8 | 4.0 | 45 | 1800 | |
| 9723-L56 | 9723-M56 | 75 | 0.008 | 1.6 | 8.0 | 24 | 960 | |
| 9723-L59 | 9723-M59 | 100 | 0.015 | 3.0 | 15 | 15 | 600 | |
| 9723-L62 | 9723-M62 | 150 | 0.035 | 7.0 | 35 | 8 | 320 | |
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
 and 200 to 1000 seconds for all other sizes
 5-fold CANNON-Ubbelohde 4-Bulb Shear Viscometers
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | Shear Rate at Wall, reciprocal seconds | |||
| Uncalibrated | Calibrated | Low | High | Low | Gigh | ||
| 9723-N50 | 9723-R50 | 25 | 0.002 | 0.4 | 2.0 | 82 | 1650 | 
| 9723-N53 | 9723-R53 | 50 | 0.004 | 0.8 | 4.0 | 45 | 900 | 
| 9723-N56 | 9723-R56 | 75 | 0.008 | 1.6 | 8.0 | 24 | 480 | 
| 9723-N59 | 9723-R59 | 100 | 0.015 | 3.0 | 15 | 15 | 300 | 
| 9723-N62 | 9723-R62 | 150 | 0.035 | 7.0 | 35 | 8 | 160 | 
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
 and 200 to 1000 seconds for all other sizes
 The Cannon Four-Bulb Shear Dilution Viscometer measures intrinsic viscosities extrapolated to zero shear rate with negligible kinetic energy correction. Minimum sample volume is 20 mL. Minimum bath depth is 280 mm (11 in). Minimum bath depth for viscometers with the 10x range of shear rates is 430 mm (17 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.
  
 8. CANNON-Manning Semi-Micro Viscometers
 The Cannon-Manning Semi-Micro Viscometer measures kinematic viscosity of small samples of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is ~1 mL (sizes 400 through 600 may require additional sample). Minimum bath depth is 200 mm (8 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | |||
| Uncalibrated | Calibrated | Low | High | |||
| 9721-X50 | 9721-Y50 | 25 | 0.002 | 0.4 | 2.0 | |
| 9721-X53 | 9721-Y53 | 50 | 0.004 | 0.8 | 4.0 | |
| 9721-X56 | 9721-Y56 | 75 | 0.008 | 1.6 | 8.0 | |
| 9721-X59 | 9721-Y59 | 100 | 0.015 | 3.0 | 15 | |
| 9721-X62 | 9721-Y62 | 150 | 0.035 | 7.0 | 35 | |
| 9721-X65 | 9721-Y65 | 200 | 0.1 | 20 | 100 | |
| 9721-X68 | 9721-Y68 | 300 | 0.25 | 50 | 250 | |
| 9721-X71 | 9721-Y71 | 350 | 0.5 | 100 | 500 | |
| 9721-X74 | 9721-Y74 | 400 | 1.2 | 240 | 1200 | |
| 9721-X77 | 9721-Y77 | 450 | 2.5 | 500 | 2500 | |
| 9721-X80 | 9721-Y80 | 500 | 8.0 | 1600 | 8000 | |
| 9721-X83 | 9721-Y83 | 600 | 20 | 4000 | 20000 | |
† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
 and 200 to 1000 seconds for all other sizes
 .
 9. CANNON-Manning Semi-Micro Extra Low Viscometers
 The Cannon-Manning Semi-Micro Extra Low Charge Viscometer measures kinematic viscosity of very small samples of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is ~0.5 mL (sizes 200 through 600 may require additional sample). Minimum bath depth is 230 mm (9 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are not available
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | |||
| Uncalibrated | Calibrated | Low | High | |||
| 9722-C50 | 9722-D50 | 25 | 0.002 | 0.4 | 2.0 | |
| 9722-C53 | 9722-D53 | 50 | 0.004 | 0.8 | 4.0 | |
| 9722-C56 | 9722-D56 | 75 | 0.008 | 1.6 | 8.0 | |
| 9722-C59 | 9722-D59 | 100 | 0.015 | 3.0 | 15 | |
| 9722-C62 | 9722-D62 | 150 | 0.035 | 7.0 | 35 | |
| 9722-C65 | 9722-D65 | 200 | 0.1 | 20 | 100 | |
| 9722-C68 | 9722-D68 | 300 | 0.25 | 50 | 250 | |
| 9722-C71 | 9722-D71 | 350 | 0.5 | 100 | 500 | |
| 9722-C74 | 9722-D74 | 400 | 1.2 | 240 | 1200 | |
| 9722-C77 | 9722-D77 | 450 | 2.5 | 500 | 2500 | |
| 9722-C80 | 9722-D80 | 500 | 8.0 | 1600 | 8000 | |
| 9722-C83 | 9722-D83 | 600 | 20 | 4000 | 20000 | |
† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
  
 10. Zeitfuchs Transparent Viscometer
The Zeitfuchs Transparent Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Filling, measurement and cleaning do not require removal from the constant temperature bath. Minimum sample volume is 15 mL. Minimum bath depth is 292 mm (11.5 in). Both calibrated and uncalibrated viscometers are available and provided with permanently attached round or rectangular metal holders. Calibrated viscometers also include a certificate of calibration and instruction sheet.
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s) | |||||
| with round metal holders* | with rectangular metal holders** | |||||||
| Uncalibrated | Calibrated | Uncalibrated | Calibrated | Low | High | |||
| 9723-A50 | 9723-B50 | 9723-C50 | 9723-D50 | 1 | 0.003 | 0.6 | 3.0 | |
| 9723-A55 | 9723-B55 | 9723-C55 | 9723-D55 | 2 | 0.01 | 2.0 | 10 | |
| 9723-A60 | 9723-B60 | 9723-C60 | 9723-D60 | 3 | 0.03 | 6.0 | 30 | |
| 9723-A65 | 9723-B65 | 9723-C65 | 9723-D65 | 4 | 0.1 | 20 | 100 | |
| 9723-A70 | 9723-B70 | 9723-C70 | 9723-D70 | 5 | 0.3 | 60 | 300 | |
| 9723-A75 | 9723-B75 | 9723-C75 | 9723-D75 | 6 | 1.0 | 200 | 1000 | |
| 9723-A80 | 9723-B80 | 9723-C80 | 9723-D80 | 7 | 3.0 | 600 | 3000 | |
† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
 * round holder is compatible with a 51 mm (2 in) diameter port
 ** rectangular holder is compatible with a bath opening of 25 mm × 48 mm (1 in × 1.9 in)
 
 11. Zeitfuchs Cross-Arm Viscometer (Reversed Flow)
 The Zeitfuchs Cross-Arm Viscometer measures kinematic viscosity of transparent and opague Newtonian liquids according to ASTM D445 and ISO 3104. Filling and cleaning does not require removal from the constant temperature bath. Minimum sample volume is 1 to 3 mL. Minimum bath depth is 230 mm (9 in). Unity factor series has a constant within ± 0.2% of the values listed. Viscometers are provided with a certificate of calibration and instruction sheet. Permanently attached round or rectangular metal holders are included or may be ordered separately
|  | Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | ||||||
| without holders | with round metal holders* | with rectangular metal holders** | Low | High | ||||||
| Standard | Unity Factor | Standard | Unity Factor | Standard | Unity Factor | |||||
| 9723-S50 | 9723-U50 | 9723-W50 | 9721-Y50 | 9724-B50 | 9724-D50 | 1 | 0.003 | 0.6 | 2.0 | |
| 9723-S53 | 9723-U53 | 9723-W53 | 9723-Y53 | 9724-B53 | 9724-D53 | 2 | 0.01 | 2.0 | 10 | |
| 9723-S56 | 9723-U56 | 9723-W56 | 9723-Y56 | 9724-B56 | 9724-D56 | 3 | 0.03 | 6.0 | 30 | |
| 9723-S59 | 9723-U59 | 9723-W59 | 9723-Y59 | 9724-B59 | 9724-D59 | 4 | 0.1 | 20 | 100 | |
| 9723-S62 | 9723-U62 | 9723-W62 | 9723-Y62 | 9724-B62 | 9724-D62 | 5 | 0.3 | 60 | 300 | |
| 9723-S65 | 9723-U65 | 9723-W65 | 9723-Y65 | 9724-B65 | 9724-D65 | 6 | 1.0 | 200 | 1000 | |
| 9723-S68 | 9723-U68 | 9723-W68 | 9723-Y68 | 9724-B68 | 9724-D68 | 7 | 3.0 | 600 | 3000 | |
| 9723-S71 | 9723-U71 | 9723-W71 | 9723-Y71 | 9724-B71 | 9724-D71 | 8 | 10 | 2000 | 10000 | |
| 9723-S74 | 9723-U74 | 9723-W74 | 9723-Y74 | 9724-B74 | 9724-D74 | 9 | 30 | 6000 | 30000 | |
| 9723-S77 | 9723-U77 | 9723-W77 | 9723-Y77 | 9724-B77 | 9724-D77 | 10 | 100 | 20000 | 100000 | |
† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
 * round holder is compatible with a 51 mm (2 in) diameter port
 ** rectangular holder is compatible with a bath opening of 25 mm × 48 mm (1 in × 1.9 in)
  
 12. BS/U-Tube Viscometer (Transparent)
 BS/U-Tube Viscometers
 The BS/U-Tube Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL (size A-C); 12 mL (size D-F); 23 mL (size G-H). Minimum bath depth is 280 mm (11 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are available in sizes G & H only (H100).
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s)† | ||
| Low | High | ||||
| 9724-E50 | A | 0.003 | 0.9 | 3.0 | |
| 9724-E53 | B | 0.01 | 2.0 | 10 | |
| 9724-E56 | C | 0.03 | 6.0 | 30 | |
| 9724-E59 | D | 0.1 | 20 | 100 | |
| 9724-E62 | E | 0.3 | 60 | 300 | |
| 9724-E65 | F | 1.0 | 200 | 1000 | |
| 9724-E68 | G | 3.0 | 600 | 3000 | |
| 9724-E71 | H | 10.0 | 2000 | 10000 | |
† Viscosity ranges in mm²/s represent flow times of 300 to 1000 seconds for size A
 and 200 to 1000 seconds for all other sizes
  
 13.  BS/U/M Miniature Viscometer (Transparent)
 The BS/U/M Miniature U-Tube Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 2 mL. Minimum bath depth is 230 mm (9 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are not available.
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s) | ||
| Low | High | ||||
| 9724-E80 | M1 | 0.001 | 0.2 | 1.0 | |
| 9724-E83 | M2 | 0.005 | 1.0 | 5.0 | |
| 9724-E86 | M3 | 0.015 | 3.0 | 15 | |
| 9724-E89 | M4 | 0.04 | 8.0 | 40 | |
| 9724-E92 | M5 | 0.1 | 20 | 100 | |
† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
  
 14. BS/IP/SL Suspended Level Viscometer
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s) | ||
| Low | High | ||||
| 9724-F10 | 1 | 0.01 | 3.5 | 10 | |
| 9724-F13 | 1A | 0.03 | 6.0 | 30 | |
| 9724-F16 | 2 | 0.1 | 20 | 100 | |
| 9724-F19 | 2A | 0.3 | 60 | 300 | |
| 9724-F22 | 3 | 1.0 | 200 | 1000 | |
| 9724-F25 | 3A | 3.0 | 600 | 3000 | |
| 9724-F28 | 4 | 10 | 2000 | 10000 | |
| 9724-F31 | 4A | 30 | 6000 | 30000 | |
| 9724-F34 | 5 | 100 | 20000 | 100000 | |
† Viscosity ranges in mm²/s represent flow times of 350 to 1000 seconds
  
 15. BS/IP/SL(S) Suspended Level Viscometer
 The BS/IP/SL(S) Suspended Level Short Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 10 mL. Minimum bath depth is 230 mm (9 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are sold separately.
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s) | ||
| Low | High | ||||
| 9724-F50 | 1 | 0.0008 | 1.05 | 1.05 | |
| 9724-F53 | 2 | 0.003 | 2.1 | 3.0 | |
| 9724-F56 | 3 | 0.01 | 3.8 | 10 | |
| 9724-F59 | 4 | 0.03 | 6.0 | 30 | |
| 9724-F62 | 5 | 0.1 | 20 | 100 | |
| 9724-F65 | 6 | 0.3 | 60 | 300 | |
| 9724-F68 | 7 | 1.0 | 200 | 1000 | |
| 9724-F71 | 8 | 3.0 | 600 | 3000 | |
| 9724-F74 | 9 | 10.0 | 2000 | 10000 | |
† Viscosity ranges in mm²/s represent a flow time of 1320 seconds (size 1),
 600 to 1000 seconds (size 2), 380 to 1000 seconds (size 3)
 and 200 to 1000 seconds for all other sizes
  
 16.  BS/IP/MSL Miniature Suspended Level Viscometer
 The BS/IP/MSL Miniature Suspended Level Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 4 mL. Minimum bath depth is 305 mm (12 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are sold separately.
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s) | ||
| Low | High | ||||
| 9724-G10 | 1 | 0.003 | 0.6 | 3.0 | |
| 9724-G13 | 2 | 0.01 | 2.0 | 10 | |
| 9724-G16 | 3 | 0.03 | 6.0 | 30 | |
| 9724-G19 | 4 | 0.1 | 20 | 100 | |
| 9724-G22 | 5 | 0.3 | 60 | 300 | |
| 9724-G25 | 6 | 1.0 | 200 | 1000 | |
| 9724-G28 | 7 | 3.0 | 600 | 3000 | |
† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
  
| Catalog Number | Size | Approximate Constant (mm²/s²) | Viscosity Range (mm²/s) | ||
| Low | High | ||||
| 9724-G50 | 1 | 0.003 | 0.6 | 3.0 | |
| 9724-G53 | 2 | 0.01 | 2.0 | 10 | |
| 9724-G56 | 3 | 0.03 | 6.0 | 30 | |
| 9724-G59 | 4 | 0.1 | 20 | 100 | |
| 9724-G62 | 5 | 0.3 | 60 | 300 | |
| 9724-G65 | 6 | 1.0 | 200 | 1000 | |
| 9724-G68 | 7 | 3.0 | 600 | 3000 | |
| 9724-G71 | 8 | 10 | 2000 | 10000 | |
| 9724-G74 | 9 | 30 | 6000 | 30000 | |
| 9724-G77 | 10 | 100 | 20000 | 100000 | |
| 9724-G80 | 11 | 300 | 60000 | 300000 | |
† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
 The BS/IP/RF U-Tube Reversed Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 280 mm (11 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are sold separately.
  
 18. Cannon-Manning Vacuum Viscometers
 The Cannon-Manning Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 6 mL. Minimum bath depth is 180 mm (7.1 in). Viscometers are provided with a certificate of calibration and instruction sheet. Permanently attached round metal holders are included or may be ordered separately.
| Catalog Number | Size | Approximate Constant (poise/sec at 300 mm Hg) | Viscosity Range (poise) | ||||
| without holder | with holder† | Bulb B | Bulb C | Low | High | ||
| 9724-H50 | 9724-L50 | 4 | 0.002 | 0.0006 | 0.036 | 0.8 | |
| 9724-H53 | 9724-L53 | 5 | 0.006 | 0.002 | 0.12 | 2.4 | |
| 9724-H56 | 9724-L56 | 6 | 0.02 | 0.006 | 0.36 | 8.0 | |
| 9724-H59 | 9724-L59 | 7 | 0.06 | 0.02 | 1.2 | 24 | |
| 9724-H62 | 9724-L62 | 8 | 0.2 | 0.06 | 3.6 | 80 | |
| 9724-H65 | 9724-L65 | 9 | 0.6 | 0.2 | 12 | 240 | |
| 9724-H68 | 9724-L68 | 10 | 2.0 | 0.6 | 36 | 800 | |
| 9724-H71 | 9724-L71 | 11 | 6.0 | 2.0 | 120 | 2400 | |
| 9724-H74 | 9724-L74 | 12 | 20 | 6.0 | 360 | 8000 | |
| 9724-H77 | 9724-L77 | 13 | 60 | 20 | 1200 | 24000 | |
| 9724-H80 | 9724-L80 | 14 | 200 | 60 | 3600 | 80000 | |
† Round holder is compatible with a 51 mm (2 in) diameter port
  
 19. Asphalt Institute Vacuum Viscometers
 The Asphalt Institute Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometers are provided with a certificate of calibration and instruction sheet. Permanently attached round metal holders are included or may be ordered separately.
| Catalog Number | Size | Approximate Constant (poise/sec at 300 mm Hg) | Viscosity Range (poise) | |||||
| without holder | with holder† | Bulb B | Bulb C | Bulb D | Low | High | ||
| 9724-R50 | 9724-T50 | 25 | 2.0 | 1.0 | 0.7 | 42 | 800 | |
| 9724-R55 | 9724-T55 | 50 | 8.0 | 4.0 | 3.0 | 180 | 3200 | |
| 9724-R60 | 9724-T60 | 100 | 32 | 16 | 10 | 600 | 12800 | |
| 9724-R65 | 9724-T65 | 200 | 128 | 64 | 40 | 2400 | 52000 | |
| 9724-R70 | 9724-T70 | 400R | 500 | 250 | 160 | 9600 | 1400000 | |
| 9724-R75 | 9724-T75 | 800R | 2000 | 1000 | 640 | 38000 | 5800000 | |
† Round holder is compatible with a 51 mm (2 in) diameter port
  
 20. Koppers Modified Vacuum Viscometers
 The Modified Koppers Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 2 mL. Minimum bath depth is 178 mm (7 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are sold separately.
  
| Catalog Number | Size | Approximate Constant (poise/sec at 300 mm Hg) | Viscosity Range (poise) | ||||
| Bulb B | Bulb C | Bulb D | Low | High | |||
| 9724-W50 | 25 | 2.0 | 1.0 | 0.7 | 42 | 800 | |
| 9724-W55 | 50 | 8.0 | 4.0 | 3.0 | 180 | 3200 | |
| 9724-W60 | 100 | 32 | 16 | 10 | 600 | 12800 | |
| 9724-W65 | 200 | 128 | 64 | 40 | 2400 | 52000 | |
| 9724-W70 | 400 | 500 | 250 | 160 | 9600 | 200000 | |
上一篇:没有了
下一篇:没有了
Copyright © 2004-2024 广州市赛拓仪器科技有限公司 备案号:粤ICP备07053378号-4
地址:广州市黄埔区崖鹰石路27号佳德科技园C栋301室 电话:020-85250202 邮箱:scitop@126.com
 
      关注我们