美国cannon粘度管测试方法:ASTM D445, ASTM D446, ASTM D2170方法,透明和不透明液体运动粘度测定法 (包括计算动力粘度),玻璃毛细管运动粘度计的规格及使用说明,沥青运动粘度的试验方法

CANNON Instrument Company® has been making glass capillary viscometers since 1938. We offer a variety of glass capillary viscometers because no single viscometer is ideally suited to every application. Use of high quality instruments ensures test reliability and accuracy. All CANNON glass capillary viscometers are traceable to a NIST calibration and manufactred in our ISO 9001-registered, A2LA-accredited laboratory. Our experienced staff is happy to assist you with viscometer selection. We offer the following viscometer types:


1. CANNON-Fenske Routine Viscometers
(凯能-芬斯克普通粘度管)
The Cannon-Fenske Routine Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 203 mm (8 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9721-A509721-B50250.0020.52.0
9721-A539721-B53500.0040.84.0
9721-A569721-B56750.0081.68.0
9721-A599721-B591000.0153.015
9721-A629721-B621500.0357.035
9721-A659721-B652000.120100
9721-A689721-B683000.2550250
9721-A719721-B713500.5100500
9721-A749721-B744001.22401200
9721-A779721-B774502.55002500
9721-A809721-B805008.016008000
9721-A839721-B8360020400020000
9721-A869721-B8665045900045000
9721-A899721-B8970010020000100000

† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes

2. CANNON-Fenske Opaque Viscometers (Reversed Flow)
凯能-芬斯克逆流粘度管
The Cannon-Fenske Opaque Viscometer measures kinematic viscosity of transparent and opaque Newtonian liquids according to ASTM D445, ISO 3104 and ASTM D2170. Minimum sample volume is 12 mL. Minimum bath depth is 230 mm (9 in). Special constant viscometers are available at additional cost. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9721-E509721-F50250.0020.42.0
9721-E539721-F53500.0040.84.0
9721-E569721-F56750.0081.68.0
9721-E599721-F591000.0153.015
9721-E629721-F621500.0357.035
9721-E659721-F652000.120100
9721-E689721-F683000.2550250
9721-E719721-F713500.5100500
9721-E749721-F744001.22401200
9721-E779721-F774502.55002500
9721-E809721-F805008.016008000
9721-E839721-F8360020400020000
9721-E869721-F8665045900045000
9721-E899721-F8970010020000100000

† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes

3. CANNON-Ubbelohde Viscometer
(凯能-乌氏粘度管)
The Cannon-Ubbelohde Viscometer, with a more rugged design than standard Ubbelohde viscometers, measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 11 mL. Minimum bath depth is 254 mm (10 in) but it must be submerged to 220 mm (8.5 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9721-J509721-K50250.0020.52.0
9721-J539721-K53500.0040.84.0
9721-J569721-K56750.0081.68.0
9721-J599721-K591000.0153.015
9721-J629721-K621500.0357.035
9721-J659721-K652000.120100
9721-J689721-K683000.2550250
9721-J719721-K713500.5100500
9721-J749721-K744001.22401200
9721-J779721-K774502.55002500
9721-J809721-K805008.016008000
9721-J839721-K8360020400020000
9721-J869721-K8665045900045000
9721-J899721-K8970010020000100000

† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds

4. Ubbelohde Viscometers
(乌氏粘度管)
The Ubbelohde Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 11 mL. Minimum bath depth is 241 mm (9.5 in). Unity factor series has a constant within /- 0.2% of the values listed. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedCalibrated,
Unity Factor
LowHigh
9721-N509721-R509721-U5000.0010.31.0
9721-N539721-R539721-U530C0.0030.63.0
9721-N569721-R569721-U560B0.0051.05.0
9721-N599721-R599721-U5910.012.010
9721-N629721-R629721-U621C0.036.030
9721-N659721-R659721-U651B0.051050
9721-N689721-R689721-U6820.120100
9721-N719721-R719721-U712C0.360300
9721-N749721-R749721-U742B0.5100500
9721-N779721-R779721-U7731.02001000
9721-N809721-R809721-U803C3.06003000
9721-N839721-R839721-U833B5.010005000
9721-N869721-R869721-U86410200010000
9721-N899721-R899721-U894C30600030000
9721-N929721-R929721-U924B501000050000
9721-N959721-R959721-U95510020000100000

† Viscosity ranges in mm²/s represent flow times of 300 to 1000 seconds for size 0
and 200 to 1000 seconds for all other sizes
The Ubbelohde Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 11 mL. Minimum bath depth is 241 mm (9.5 in). Unity factor series has a constant within /- 0.2% of the values listed. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

5. CANNON-Ubbelohde Dilution Viscometers
凯能-乌氏粘度管 (稀释型)
The Cannon-Ubbelohde Dilution Viscometer measures intrinsic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 8 mL (can be diluted to 40 mL). Minimum bath depth is 305 mm (12 in). The CANNON CT-518 bath is recommended. (CT-500 and CT-600 baths are not deep enough.) Viscometer constant is the same at all temperatures. Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9722-L509722-M50250.0020.52.0
9722-L539722-M53500.0040.84.0
9722-L569722-M56750.0081.68.0
9722-L599722-M591000.0153.015
9722-L629722-M621500.0357.035
9722-L659722-M652000.120100
9722-L689722-M683000.2550250
9722-L719722-M713500.5100500
9722-L749722-M744001.22401200
9722-L779722-M774502.55002500
9722-L809722-M805008.016008000
9722-L839722-M8360020400020000

† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes

6. CANNON-Ubbelohde Semi-Micro Viscometers
凯能-乌氏半微量粘度管
The Cannon-Ubbelohde Semi-Micro Viscometer measures kinematic viscosity of small samples of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is ~1 mL (sizes 400 through 600 may require additional sample). Initial sample can be diluted as much as 20 mL for intrinsic viscosity determinations. Minimum bath depth is 240 mm (9.5 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9722-G509722-H50250.0020.42.0
9722-G539722-H53500.0040.84.0
9722-G569722-H56750.0081.68.0
9722-G599722-H591000.0153.015
9722-G629722-H621500.0357.035
9722-G659722-H652000.120100
9722-G689722-H683000.2550250
9722-G719722-H713500.5100500
9722-G749722-H744001.22401200
9722-G779722-H774502.55002500
9722-G809722-H805008.016008000
9722-G839722-H8360020400020000

† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes
7. 10-fold CANNON-Ubbelohde 4-Bulb Shear Viscometers

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†Shear Rate at Wall, reciprocal seconds
UncalibratedCalibratedLowHighLowHigh
9723-L509723-M50250.0020.42.0823300
9723-L539723-M53500.0040.84.0451800
9723-L569723-M56750.0081.68.024960
9723-L599723-M591000.0153.01515600
9723-L629723-M621500.0357.0358320

† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes
5-fold CANNON-Ubbelohde 4-Bulb Shear Viscometers

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†Shear Rate at Wall, reciprocal seconds
UncalibratedCalibratedLowHighLowGigh
9723-N509723-R50250.0020.42.0821650
9723-N539723-R53500.0040.84.045900
9723-N569723-R56750.0081.68.024480
9723-N599723-R591000.0153.01515300
9723-N629723-R621500.0357.0358160

† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes
The Cannon Four-Bulb Shear Dilution Viscometer measures intrinsic viscosities extrapolated to zero shear rate with negligible kinetic energy correction. Minimum sample volume is 20 mL. Minimum bath depth is 280 mm (11 in). Minimum bath depth for viscometers with the 10x range of shear rates is 430 mm (17 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately.

8. CANNON-Manning Semi-Micro Viscometers
The Cannon-Manning Semi-Micro Viscometer measures kinematic viscosity of small samples of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is ~1 mL (sizes 400 through 600 may require additional sample). Minimum bath depth is 200 mm (8 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are sold separately

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9721-X509721-Y50250.0020.42.0
9721-X539721-Y53500.0040.84.0
9721-X569721-Y56750.0081.68.0
9721-X599721-Y591000.0153.015
9721-X629721-Y621500.0357.035
9721-X659721-Y652000.120100
9721-X689721-Y683000.2550250
9721-X719721-Y713500.5100500
9721-X749721-Y744001.22401200
9721-X779721-Y774502.55002500
9721-X809721-Y805008.016008000
9721-X839721-Y8360020400020000

† Viscosity ranges in mm²/s represent flow times of 250 to 1000 seconds for size 25
and 200 to 1000 seconds for all other sizes
.
9. CANNON-Manning Semi-Micro Extra Low Viscometers
The Cannon-Manning Semi-Micro Extra Low Charge Viscometer measures kinematic viscosity of very small samples of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is ~0.5 mL (sizes 200 through 600 may require additional sample). Minimum bath depth is 230 mm (9 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. Holders are not available

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
UncalibratedCalibratedLowHigh
9722-C509722-D50250.0020.42.0
9722-C539722-D53500.0040.84.0
9722-C569722-D56750.0081.68.0
9722-C599722-D591000.0153.015
9722-C629722-D621500.0357.035
9722-C659722-D652000.120100
9722-C689722-D683000.2550250
9722-C719722-D713500.5100500
9722-C749722-D744001.22401200
9722-C779722-D774502.55002500
9722-C809722-D805008.016008000
9722-C839722-D8360020400020000

† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds

10. Zeitfuchs Transparent Viscometer

BS/IP/MSL Miniature Suspended Level Viscometers

The Zeitfuchs Transparent Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Filling, measurement and cleaning do not require removal from the constant temperature bath. Minimum sample volume is 15 mL. Minimum bath depth is 292 mm (11.5 in). Both calibrated and uncalibrated viscometers are available and provided with permanently attached round or rectangular metal holders. Calibrated viscometers also include a certificate of calibration and instruction sheet.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)
with round
metal holders*
with rectangular
metal holders**
UncalibratedCalibratedUncalibratedCalibratedLowHigh
9723-A50 9723-B509723-C509723-D5010.0030.63.0
9723-A559723-B559723-C559723-D5520.012.010
9723-A609723-B609723-C609723-D6030.036.030
9723-A659723-B659723-C659723-D6540.120100
9723-A709723-B709723-C709723-D7050.360300
9723-A759723-B759723-C759723-D7561.02001000
9723-A809723-B809723-C809723-D8073.06003000

† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
* round holder is compatible with a 51 mm (2 in) diameter port
** rectangular holder is compatible with a bath opening of 25 mm × 48 mm (1 in × 1.9 in)

11. Zeitfuchs Cross-Arm Viscometer (Reversed Flow)
The Zeitfuchs Cross-Arm Viscometer measures kinematic viscosity of transparent and opague Newtonian liquids according to ASTM D445 and ISO 3104. Filling and cleaning does not require removal from the constant temperature bath. Minimum sample volume is 1 to 3 mL. Minimum bath depth is 230 mm (9 in). Unity factor series has a constant within ± 0.2% of the values listed. Viscometers are provided with a certificate of calibration and instruction sheet. Permanently attached round or rectangular metal holders are included or may be ordered separately

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
without holderswith round metal holders*with rectangular metal holders**LowHigh
StandardUnity FactorStandardUnity FactorStandardUnity Factor
9723-S509723-U509723-W509721-Y509724-B509724-D5010.0030.62.0
9723-S539723-U539723-W539723-Y539724-B539724-D5320.012.010
9723-S569723-U569723-W569723-Y569724-B569724-D5630.036.030
9723-S599723-U599723-W599723-Y599724-B599724-D5940.120100
9723-S629723-U629723-W629723-Y629724-B629724-D6250.360300
9723-S659723-U659723-W659723-Y659724-B659724-D6561.02001000
9723-S689723-U689723-W689723-Y689724-B689724-D6873.06003000
9723-S719723-U719723-W719723-Y719724-B719724-D71810200010000
9723-S749723-U749723-W749723-Y749724-B749724-D74930600030000
9723-S779723-U779723-W779723-Y779724-B779724-D771010020000100000

† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
* round holder is compatible with a 51 mm (2 in) diameter port
** rectangular holder is compatible with a bath opening of 25 mm × 48 mm (1 in × 1.9 in)

12. BS/U-Tube Viscometer (Transparent)
BS/U-Tube Viscometers
The BS/U-Tube Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL (size A-C); 12 mL (size D-F); 23 mL (size G-H). Minimum bath depth is 280 mm (11 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are available in sizes G & H only (H100).

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)†
LowHigh
9724-E50A0.0030.93.0
9724-E53B0.012.010
9724-E56C0.036.030
9724-E59D0.120100
9724-E62E0.360300
9724-E65F1.02001000
9724-E68G3.06003000
9724-E71H10.0200010000

† Viscosity ranges in mm²/s represent flow times of 300 to 1000 seconds for size A
and 200 to 1000 seconds for all other sizes

13.  BS/U/M Miniature Viscometer (Transparent)
The BS/U/M Miniature U-Tube Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 2 mL. Minimum bath depth is 230 mm (9 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are not available.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)
LowHigh
9724-E80M10.0010.21.0
9724-E83M20.0051.05.0
9724-E86M30.0153.015
9724-E89M40.048.040
9724-E92M50.120100

† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds

14. BS/IP/SL Suspended Level Viscometer

The BS/IP/SL Suspended Level Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 11 mL. Minimum bath depth is 250 mm (10 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)
LowHigh
9724-F1010.013.510
9724-F131A0.036.030
9724-F1620.120100
9724-F192A0.360300
9724-F2231.02001000
9724-F253A3.06003000
9724-F28410200010000
9724-F314A30600030000
9724-F34510020000100000

† Viscosity ranges in mm²/s represent flow times of 350 to 1000 seconds

15. BS/IP/SL(S) Suspended Level Viscometer
The BS/IP/SL(S) Suspended Level Short Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 10 mL. Minimum bath depth is 230 mm (9 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)
LowHigh
9724-F5010.00081.051.05
9724-F5320.0032.13.0
9724-F5630.013.810
9724-F5940.036.030
9724-F6250.120100
9724-F6560.360300
9724-F6871.02001000
9724-F7183.06003000
9724-F74910.0200010000

† Viscosity ranges in mm²/s represent a flow time of 1320 seconds (size 1),
600 to 1000 seconds (size 2), 380 to 1000 seconds (size 3)
and 200 to 1000 seconds for all other sizes

16.  BS/IP/MSL Miniature Suspended Level Viscometer
The BS/IP/MSL Miniature Suspended Level Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 4 mL. Minimum bath depth is 305 mm (12 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)
LowHigh
9724-G1010.0030.63.0
9724-G1320.012.010
9724-G1630.036.030
9724-G1940.120100
9724-G2250.360300
9724-G2561.02001000
9724-G2873.06003000

† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds

17.  BS/IP/RF U-Tube Viscometers

Catalog NumberSizeApproximate Constant
(mm²/s²)
Viscosity Range (mm²/s)
LowHigh
9724-G5010.0030.63.0
9724-G5320.012.010
9724-G5630.036.030
9724-G5940.120100
9724-G6250.360300
9724-G6561.02001000
9724-G6873.06003000
9724-G71810200010000
9724-G74930600030000
9724-G771010020000100000
9724-G801130060000300000

† Viscosity ranges in mm²/s represent flow times of 200 to 1000 seconds
The BS/IP/RF U-Tube Reversed Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 280 mm (11 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are sold separately.

18. Cannon-Manning Vacuum Viscometers
The Cannon-Manning Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 6 mL. Minimum bath depth is 180 mm (7.1 in). Viscometers are provided with a certificate of calibration and instruction sheet. Permanently attached round metal holders are included or may be ordered separately.

Catalog NumberSizeApproximate Constant
(poise/sec at 300 mm Hg)
Viscosity Range
(poise)
without holderwith holder†Bulb BBulb CLowHigh
9724-H509724-L5040.0020.00060.0360.8
9724-H539724-L5350.0060.0020.122.4
9724-H569724-L5660.020.0060.368.0
9724-H599724-L5970.060.021.224
9724-H629724-L6280.20.063.680
9724-H659724-L6590.60.212240
9724-H689724-L68102.00.636800
9724-H719724-L71116.02.01202400
9724-H749724-L7412206.03608000
9724-H779724-L77136020120024000
9724-H809724-L801420060360080000

† Round holder is compatible with a 51 mm (2 in) diameter port

19. Asphalt Institute Vacuum Viscometers
The Asphalt Institute Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometers are provided with a certificate of calibration and instruction sheet. Permanently attached round metal holders are included or may be ordered separately.

Catalog NumberSizeApproximate Constant
(poise/sec at 300 mm Hg)
Viscosity Range
(poise)
without holderwith holder†Bulb BBulb CBulb DLowHigh
9724-R509724-T50252.01.00.742800
9724-R559724-T55508.04.03.01803200
9724-R609724-T6010032161060012800
9724-R659724-T652001286440240052000
9724-R709724-T70400R50025016096001400000
9724-R759724-T75800R20001000640380005800000

† Round holder is compatible with a 51 mm (2 in) diameter port

20. Koppers Modified Vacuum Viscometers
The Modified Koppers Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 2 mL. Minimum bath depth is 178 mm (7 in). Viscometers are provided with a certificate of calibration and instruction sheet. Holders are sold separately.

Catalog NumberSizeApproximate Constant (poise/sec at 300 mm Hg)Viscosity Range (poise)
Bulb BBulb CBulb DLowHigh
9724-W50252.0 1.00.742800
9724-W55508.04.03.01803200
9724-W6010032161060012800
9724-W652001286440240052000
9724-W704005002501609600200000


 